KB-023: Node Conntrack Table Saturates from a Host-Network Scanner

Status: Resolved for scanopy (scoped to the LAN NIC + single Deployment); the rule generalizes to any host-network sweeper.

Symptom

NodeHighNumberConntrackEntriesUsed (warning) fires on every node at once, conntrack tables sit at ~100% (e.g. 262144/262144), and new connections start dropping cluster-wide. The trigger is deploying a network scanner / sweeper.

Cause

A scanner running with hostNetwork: true in a poll/daemon mode auto-scans every subnet its host has an interface on. On a Talos/Cilium node that includes the cilium virtual interfaces, and therefore the pod CIDR 10.42.0.0/16 + service CIDR 10.43.0.0/16 (~131k IPs). At the default scan rate it port-scans the entire internal cluster network; run as a DaemonSet across all control-plane nodes, it saturates every node's conntrack table.

A full conntrack table drops new connections cluster-wide: this is a whole-cluster hazard, not just a scanner problem. (Stopping the scanner drains conntrack back to <2% within ~3 min, which confirms it is the sole cause.)

Fix

  • Scope the scanner to the physical LAN NIC so it never sees the Cilium CIDRs (the big lever):
SCANOPY_INTERFACES=<lan-nic>   # --interfaces; default = ALL interfaces

Verify the NIC name is identical on all nodes before hardcoding it in a workload (different hardware can enumerate interfaces differently). - Prefer a single-replica Deployment over a DaemonSet on a flat LAN. One scanner covers the whole /24; a per-node DaemonSet triples the load scanning the same subnet. (scanopy: use strategy: Recreate + a stable SCANOPY_NAME.) - Cap concurrency (SCANOPY_CONCURRENT_SCANS, default auto ~10-20) and set a conservative per-discovery Speed profile. Newer scanopy moved per-scan rate (scan-rate-pps, port batch) to the UI per-discovery "Speed" tab; daemon-level rate flags are ignored. - Optional headroom: raise net.netfilter.nf_conntrack_max via Talos machine.sysctls.

General rule: any hostNetwork scanner/sweeper on this cluster must be scoped to the physical NIC / real LAN. Never let it discover the Cilium pod/service CIDRs.

How to recognise fast

  • The conntrack alert appears immediately after deploying/enabling a scanner, on all nodes simultaneously. Emergency relief: flux suspend hr <scanner> and park the workload (nodeSelector → no nodes) to drain conntrack, then re-deploy scoped.
  • VLAN caveat: SCANOPY_INTERFACES only scopes L2 / local-interface scanning. The scanner still L3-scans remote routable subnets it discovers via SNMP routing tables, so as new VLANs come online and become routable, conntrack load can climb again. Narrow scope per-discovery in the UI and keep nf_conntrack_max headroom. Re-check conntrack after a VLAN buildout.

References